Unable to open file
Technical Note 20773
Arkitekturer:
8051
Komponent:
linker
Uppdaterad:
2018-05-31 09:14
Introduction
This tech note relates to an issue that can occur when using SimpliciTI from Texas Instruments.
Issue
IAR Embedded Workbench for 8051 gives a message similar to
Error[e12]: Unable to open file 'C:\Program Files\IAR Systems\Embedded Workbench 6.0\8051\config\< filename >.xcl'
when attempting to build a SimpliciTI project written for a specific (previous) version of IAR Embedded Workbench.
Possible solution
Locate the proper linker xcl-file and specify the appropriate location in project options.
Follow the link to a Texas Instruments FAQ-answer illustrating this.
Explanation and information
The problem is simply happening if the project uses a path for the .xcl
file, where that path no longer exists on the current computer. That can happen after an override of the default files for the chip device. It can also happen if the project was made for an older version of IAR Embedded Workbench for 8051 and the project is now opened in a newer version.
Read more about .xcl
files in the IAR XLINK Linker manual (xlink.ENU.pdf
) in your installation.